Yokogawa EJA118E Differential Pressure Transmitter With Remote Diaphragm Seals

Yokogawa EJA118E Differential Pressure Transmitter With Remote Diaphragm Seals

  • Yokogawa EJA118E Differential Pressure Transmitter With Remote Diaphragm Seals
Yokogawa EJA118E Differential Pressure Transmitter With Remote Diaphragm Seals
Product Details:
Place of Origin: Made In Japan
Brand Name: YOKOGAWA
Model Number: EJA118E
Payment & Shipping Terms:
Minimum Order Quantity: Negotiation
Price: Negotiation
Packaging Details: Each set packed in one carton
Delivery Time: 8weeks
Payment Terms: T/T, Western Union, MoneyGram
Supply Ability: 50sets 6weeks
Contact Now
Detailed Product Description
Name: EJA118E Differential Pressure Transmitter Accuracy: ± 0.2%
Measurement Range: 3,600 Psi MWP Response Time: 200 Ms
Primary Variable: Differential Pressure Secondary Variable: Static Pressure
Output Signal: 4 To 20 MA DC With Digital Communication Measurement Span: H: -5 To 5 Kgf/cm2
High Light:

diff pressure transmitter

,

pressure differential indicating transmitter

,

Diaphragm Seals Differential Pressure Transmitter

Yokogawa EJA118E Differential Pressure Transmitter with Remote Diaphragm Seals

 

General Specifications

Diaphragm seals are used to prevent process medium form entering directly into the pressure-sensing assembly

of the differential pressure transmitter, they are connected to the transmitter using capillaries filled with fill fluid.

EJA118E Diaphragm Sealed Differential Pressure Transmitters can be used to measure liquid, gas,or steam flow,

as well as liquid level, density, and pressure. EJA118E outputs a 4 to 20 mA DC signal corresponding to the

measured differential pressure.

Its highly accurate and stable sensor can also measure the static pressure which can be shown on the integral

indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response,

remote set-up using communications,and self-diagnostics.

FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 VDC with HART (Low Power) protocol types are also available.

EJA-E series models in their standard configuration, with the exception of the Fieldbus,PROFIBUS and Low Power

types, are certified as complying with SIL 2 for safety requirement.

 

STANDARD SPECIFICATIONS

EJA118E Diaphragm Sealed Differential Pressure Transmitter

 

SPAN AND RANGE LIMITS

Measurement
Span/Range
kPa inH2O
(/D1)
mbar
(/D3)
mmH2O
(/D4)
M Span 2.5 to 100 10 to 400 25 to 1000 250 to 10000
Range -100 to 100 -400 to 400 -1000 to 1000 -10000 to 10000
H Span 25 to 500 100 to 2000 250 to 5000 0.25 to 5kgf/cm2
Range -500 to 500 -2000 to 2000 -5000 to 5000 -5 to 5kgf/cm2

 

PERFORMANCE SPECIFICATIONS

Zero-based calibrated span, linear output, wetted parts material code SW for 3-inch flange flush type, fill fluid code B,

and capillary length of 5 m.

For Fieldbus and PROFIBUS communication types, use caribrated range instead of span in the following specifications.

Specification Conformance

EJA-E series ensures specification conformance to at least ±3σ.

 

Reference Accuracy of Calibrated Span

Includes terminal-based linearity, hysteresis, and repeatability

Measurement span H
Reference
accuracy
X span ±0.2% of Span
X > span ±(0.15+0.01 URL/span)% of Span
X 100 kPa (400 inH2O)
URL
(upper range limit)
500 kPa (2000 inH2O)

 

 

Measurement span H
Reference
accuracy
X span ±0.2% of Span
X > span ±(0.15+0.01 URL/span)% of Span
X 20 kPa (80 inH2O)
URL
(upper range limit)
100 kPa (400 inH2O)

 

Square Root Output Accuracy

The square root accuracy is a percent of flow span.

 

Output Accuracy
50% or Greater Same as reference accuracy
50% to Dropout point Reference accuracy × 50
Square root output (%)

 

Power Supply Effects(Output signal code D and J)

±0.005 % per Volt (from 21.6 to 32 V DC, 350Ω)

Response Time (Differential pressure) “◊”

M and H capsule: 200 ms (approximate value at normal temperature)

When software damping is set to zero and including dead time of 45 ms (nominal)

Static Pressure Signal Range and Accuracy

(For monitoring via communication or on indicator. Includes terminal-based linearity,hysteresis, and repeatability)

Range

Upper Range Value and Lower Range Value of the statice pressure can be set in the range between 0 and Maximum Working Pressure (MWP*). The upper range value must be greater than the lower range value. Minimum setting span is 0.5 MPa (73 psi).

* : Maximum Working Pressure (MWP) is within flange rating pressure.

EJA118E Specification Overview

Refer to the General Specification sheet located under the 'Downloads' tab for detailed specifications.

Measurement Types
Primary Variable Differential Pressure
Secondary Variable Static Pressure
Reference Accuracy
Primary Variable ±0.04% of Span
±0.025% of Span available
Secondary Variable ±0.2% of Span
Response Time
Primary Variable 90 msec
Secondary Variable 360 msec
Long Term Stability
Primary Variable ±0.1% of URL per 10 years
Over-pressure effect
Primary Variable ±0.03% of URL
Rangeability
Primary Variable 200:1

 

Yokogawa EJA118E Differential Pressure Transmitter With Remote Diaphragm Seals 0 